Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard

Ask Latest Price
Brand Name :Kinte
Model Number :WH-8820C
Certification :Certificate of conformity of quality management system certification
Place of Origin :Guangdong,China (Mainland)
MOQ :1set
Price :customized
Supply Ability :customized
Delivery Time :customized
Packaging Details :customized
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard​

Test standard:

In line with China's national standard GB18380.1_2001 "cable in the flame under the conditions

of the combustion test Part I: single insulated or vertical cable burning test method", the

equivalent use of IEC60332-1.

Applicable to the determination of a single plastic line, control, cross-linked, elevators, marine,

mining cables and other non-retardant properties. And can do a high self-extinguishing low-

smoke halogen-free flame retardant polyolefin insulation materials and 105 ℃ low-smoke

halogen-free flame retardant olefin insulation materials vertical burning test.

Features:

The device can automatically ignite and close the test flame, automatic timing, automatic end of

the test, high accuracy, easy operation and so on. This equipment consists of control box,

combustion box, propane combustion lamp, solenoid valve, high voltage igniter, gas pipe,

pressure regulating valve, gas flow meter (propane and air) and signal control line.

The main parameters:

1, vertical combustion box: box size W300xH1200xD450mm;

2, gas: the use of high-purity propane gas or liquefied petroleum gas (user-owned);

3, be tested wire and cable length: 600 ± 25mm;

4, the test wire and cable diameter: conductor diameter greater than 0.8mm or cross-sectional

area greater than 0.5mm2;

5, the device should be placed in a non-ventilated and temperature (23 ± 10) ℃ environment for

testing;

6, the flame should be continuous burning of the sample, the flame burning time T Setting range

0.1-999.9 (seconds) continuous set;

7, the switch can be selected according to actual needs of manual or automatic;

8, gas flow range: 0.1-1L / min;

9, the air flow range: 0.1-1m3 / h

10, burning torch standard power: 1KW;

11, the power supply voltage: 220V / 50Hz;

Single Wire Line Vertical Flame Test Chamber With Gb18380.1_2001 Standard