Add to Cart
20 Drops - 50 Drops Flammability Testing Equipment WH-8902JK Leakage Tracking Test
Leakage tracking test is the IEC60112: 2003 "solid insulation material resistance to tracking
index and compared to the determination of trace index", UL 746A, ASTM D 3638-92, DIN
53480 standards such as simulation test project.
The tracking test was carried out by dropping a predetermined droplet volume of a
contaminated
liquid (0.1 (0.1 mm)) at a predetermined height (35 mm) between a predetermined size (2
mm x
5 mm) of platinum electrodes on a solid insulating material surface, applying a voltage, %
NH 4
CL) was used to evaluate the ability of the surface of the solid insulating material to combine
with the electric field and the contaminating medium, and to compare the electrical tracing
index
(CT1) and the tracking resistance index (PT1).
Electrical traceability testing instrument for lighting equipment, low-voltage electrical
appliances,
household appliances, electrical appliances, electrical, electrical tools, electronic equipment,
electrical instruments, information technology equipment research, production and quality
inspection departments, also applies to insulation materials, engineering Plastics, electrical
connections, accessories industry.
Performance parameters
Electrode material test electrode - platinum, electrode post - silver
Electrode size (2mm ± 0.1mm) × (5mm ± 0.1mm) × (40mm ± 5mm), platinum electrode
12mm,
30 ° ± 2 ° bevel;
Electrode distance 4.0mm ± 0.01mm, the angle of 60 ° ± 5 °;
Electrode pressure 1.00N ± 0.001N;
Test solution resistance A solution 0.1% NH4Cl, 3.95 ± 0.05Ωm, B solution 1.98 ± 0.05Ωm;
Droplet volume 20 drops 0.380g ~ 0.480g, 50 drops 0.997g ~ 1.147g (can be finely
adjusted);
Droplet height of 35mm ± 5mm (adjustable);
Droplet time 30s ± 0.1s (better than standard) (digital display, can be preset to adjust), 50 drops
of time 24.5min ± 2min;
Droplet number of 1 to 9999 (digital display, can be preset);
Test wind speed 0.2m / s (new standard);
Test voltage 100V ~ 600V (25V indexing, adjustable);
Power supply voltage drop 1.0A ± 0.1A 8%;
From the mark to determine 0.50A ± 10%, 2.00s ± 10%;
Dimensions: Width 1120mm × depth 520mm × height 1350mm, the exhaust aperture
Φ100mm;
Test power supply 220V 0.6kVA 50-60Hz